ATX400 - Safety Circuit Module
ATX400 safety circuit module provides monitoring of parametric safety circuit, which status reflects to output contacts of the module. Monitored safety circuit consists of 2 current loops ended with terminators based on ATX302 circuit. The construction of the module allows it to be used to separate intrinsically safe and nonintrinsically safe circuit. To provide appropriate intrinsically safe feature the module should be placed inside a casing with at least Ip54 protection degree or in a flameproof casing. ATX400 module is produced in version for supply voltage 12 V (ATX400/12) and in version for supply voltage 15 V (ATX400/15).
Technical data
Supply parameters: | ATX400/12 |
Supply voltage | 10,5 ÷ 12 VDC |
Maximum supply voltage U | 12,8 VDC |
Supply current I | < 140 mA |
Maximum supply current I | 2,55 A |
Controlled circuit parameters: | ATX400/12 |
U = 12,8 V | |
I = 240 mA | |
L = 13 mH | |
C = 2 μF | |
Supply parameters: | ATX400/15 |
Supply voltage U | 12,5 ÷ 15 VDC |
Maximum supply voltage U | 15,8 VDC |
Supply current I | < 130 mA |
Maximum supply current I | 2,55 A |
Controlled circuit parameters: | ATX400/15 |
U = 15,8 V | |
I= 240 mA | |
L = 13 mH | |
C = 2 μF | |
Normal working conditions: | for ATX400/12 and ATX400/15 |
Casing type: | |
-for devices with IP54 casing | I M1 Ex ia I Ma |
-for devices with flameproof casing | I (M1) [EX ia Ma] I |
Working temperature range | 0°С ÷ 70°С |
Gallery
×
Documents to download
2,16 MB | en-atx400.pdf | Download |