ATX470 - Intrinsically Safe Modem
ATX470 module is a modem that provides data transmission through intrinsically safe telephone line. The modem connects through terminals on one side with telephone line and with serial data transmission devices on the other side. The module is equipped with two RS422 interfaces. Data transmission speed in telephone line, depending on the link status, reaches values up to 33 600 bps. The module has independent certificate from certification body that confirms meeting the requirements of ATEX Directive, what allows the modem to be used in an hardware configuration. The construction of the module meets the requirements of IEC61131 norm in range of standarization of functional and operational features and programming process. To keep appropriate intrinsically safe feature the module should be placed in a casing with at least IP54 protection degree and meeting the requirements of EN 60079-11:2012 norm.
Technical data
ATEX certificate number |
FTZÚ 13 ATEX 0198X |
Supply parameters: |
|
Supply voltage U |
6,5 ÷ 15 VDC |
Maximum supply voltage U |
15,8 VDC |
Maximum supply current I |
2,73 A |
Maximum current draw from battery IAK |
|
for U = 6,5 V |
< 150 mA |
for U = 15 V |
< 75 mA |
Data transmission mode |
duplex |
Transmission |
single-pair leased lines |
Transmission inputs/outputs |
|
- modem transmission - telephone line: |
|
- maximum transmission line distance |
up to 20 km (depending on line status) |
- maximum transmission speed |
33 600 bps |
- serial transmission - 2 x RS422: |
|
- maximum transmission line distance |
up to 2 km (depending on line status) |
- maximum transmission speed |
115 200 bps |
Local communication bus |
RS485 / CAN / I2C (possible versions of module implementation) |
Transmission speed for interfaces: |
|
I2C |
100 000 bps |
RS485 |
9600, 19200, 38400, 57600, 115200 bps |
CAN |
20000,50000, 125000, 250000, 500000,1000000 bps |
Normal working conditions: |
|
Casing type |
I M1 Ex ia I Ma module placed in device with Ip54 protection degree and meeting the requirements of EN 60079-11:2012 norm |
Working temperature range |
0 ÷ 60 ⁰C |