CUKS-4/N - Digital Control Device series
Digital Control Device Type CUKS-4 is designed to control industrial processes under the atmosphere of steam, gases and dusts posing a risk of explosion. It is designed both to work independently as well as in a digital network system, then being a part of a larger system. Implementation of the device enables connectivity of loud speaking, signaling and measurement of selected voltages associated with diagnostic system. The integrated battery allows continuous operation in spite of temporary power outages. Its equipment provides the ability to control and drive by two inputs and one output , and tension control of the emergency stop cord. Device is made as intrinsically safe, allowing their use in mining in areas with danger of explosion of methane and / or coal dust.
Technical data
ATEX certificate number |
FTZÚ 09 ATEX 0237 |
Supply parameters: |
|
Supply voltage U |
12,5 ÷ 15 VDC |
Maximum supply voltage U |
15,8 VDC |
Supply parameters |
I =2,5A C =0, L =0; |
Supply Current I I |
< 120 mA ( CUKS-4/..W/XY ) |
|
I < 100 mA ( CUKS-4/../XY ) N |
|
I < 80 mA ( CUKS-4/..1..) N |
|
I < 80 mA ( CUKS-4/..2..) N |
|
I < 70 mA ( CUKS-4/..0..W ) N |
|
I < 50 mA ( CUKS-4/..0.. ) N |
Binary input circuits (I 1 ÷ I 2) |
U = 14,28V N N I MAX |
voltage inputs |
0 ... 10 V |
current inputs |
4 ... 20 mA |
frequency inputs |
5 ... 15 Hz |
temperature inputs |
-30 .. 300°C (PT1000) |
Output circuit (OUT) |
U = U (12 ÷ 15 VDC) |
|
U = 0 ÷ 0,1 VDC L |
|
U = 15,8 VDC 0 |
Device Group |
I |
Device category |
M2/M1 |
Casing type |
Ex ib/ia I |
Working temperature range |
0°C ÷ 40°C |
Casing protection degree |
IP65 |
Width x Height x Depth |
459 x 473 x 123 mm |
Weight |
6 kg |